What certifications should an automated sample preparation system meet?
Automated sample preparation systems should meet several key certifications and standards before they are used in regulated laboratory environments. At minimum, equipment intended for professional analytical use must carry CE marking (for the European market), comply with relevant ISO standards governing laboratory equipment and quality management, and support IQ/OQ/PQ qualification protocols required by accredited labs. The specific certifications that matter most depend on the application, whether the system is used for PFAS, dioxin, PCB, or pesticide analysis, and the regulatory framework the laboratory operates under. The sections below address each of the most common questions laboratories ask when evaluating automated sample prep equipment.
Which ISO standards apply to automated sample preparation systems?
Several ISO standards are relevant to automated sample preparation systems, depending on whether the focus is on the equipment itself, the laboratory using it, or the analytical methods it supports. The most important are ISO/IEC 17025, which governs laboratory competence and accreditation, and ISO 9001, which covers quality management systems at the manufacturer level. Equipment used in accredited labs must be compatible with the validation and traceability requirements these standards impose.
ISO/IEC 17025 does not certify instruments directly, it accredits the laboratory and its methods. However, it requires that all equipment used in testing be fit for purpose, properly calibrated, and fully documented. This means any automated sample preparation system deployed in an ISO 17025-accredited lab must be qualified, maintained, and traceable to reference standards.
On the manufacturer side, ISO 9001:2015 certification signals that the company producing the equipment operates under a documented quality management system. For analytical standards and reference materials used alongside sample prep systems, ISO Guide 34 (now replaced by ISO 17034) and ISO/IEC 17025 at the producer level are the relevant benchmarks. When evaluating equipment, laboratories should ask whether the manufacturer holds ISO 9001 certification and whether the system’s design supports the traceability requirements of ISO/IEC 17025.
What does CE marking mean for laboratory automation equipment?
CE marking indicates that a piece of laboratory automation equipment conforms to the applicable European Union directives covering health, safety, and environmental protection. For automated sample preparation systems sold in Europe, CE marking is a legal requirement, not an optional quality indicator. It confirms the equipment has been assessed against directives such as the Machinery Directive, the Low Voltage Directive, and the Electromagnetic Compatibility (EMC) Directive, as applicable to the device.
CE marking does not mean the equipment has been tested by an independent third party in all cases, for many product categories, manufacturers can self-declare conformity after conducting their own assessment. However, it does mean the manufacturer has produced a Declaration of Conformity and maintains a technical file documenting how the product meets each relevant directive’s requirements.
For laboratory buyers, CE marking is a baseline requirement for equipment purchased for use within the EU or EEA, but it should not be confused with performance validation or method suitability. A CE-marked system is legally compliant for the market, but laboratories still need to qualify and validate it for their specific analytical methods and matrices.
Are there specific certifications for systems used in PFAS or dioxin analysis?
There are no single universal certifications exclusive to PFAS or dioxin analysis systems, but equipment used in these applications must be compatible with the regulatory methods that govern them. In the United States, EPA methods such as EPA 537.1 and EPA 533 (for PFAS in drinking water), EPA 1613B (for dioxins and furans), and EPA 1668A (for PCBs) define the analytical requirements that sample preparation systems must support. In Europe, CEN standards and EU regulations set the framework for food, feed, water, and environmental matrices.
PFAS-specific material requirements
For PFAS analysis, the material composition of the sample preparation system is critically important. PFAS compounds can adsorb onto or leach from certain plastics, including PTFE (Teflon), which means systems with fully inert, Teflon-free flow paths are strongly preferred. Laboratories evaluating automated SPE systems for PFAS work should verify that all wetted surfaces are chemically inert and that the system has been validated against relevant EPA or EN methods.
Dioxin and PCB cleanup requirements
For dioxin and PCB analysis, the key performance criteria are selectivity, recovery, and the absence of cross-contamination. Systems used in this context are typically evaluated against EU Regulation 2019/1793 and its predecessors for food and feed, or against EPA 1613B for environmental samples. Peer-reviewed validation data published against these methods, such as those available in the scientific literature for the GO-EHT platform, provides stronger assurance than a certification label alone.
What is IQ/OQ/PQ qualification and when is it required?
IQ/OQ/PQ stands for Installation Qualification, Operational Qualification, and Performance Qualification. Together, these three stages form a structured validation process that confirms a laboratory instrument is correctly installed, operates as intended, and consistently performs within the specifications required for its intended analytical use. IQ/OQ/PQ qualification is required whenever a laboratory operates under a quality framework such as ISO/IEC 17025, GMP, or GLP, or when regulatory submissions depend on the data generated by the instrument.
Installation Qualification (IQ) documents that the system has been delivered and installed according to the manufacturer’s specifications, covering hardware, software, utilities, and environmental conditions.
Operational Qualification (OQ) verifies that the system operates correctly across its defined operating range. This typically involves testing functions, alarms, and performance parameters against documented acceptance criteria.
Performance Qualification (PQ) confirms that the system consistently performs as required under actual working conditions, using real or representative samples and the laboratory’s own methods.
For automated sample preparation systems used in accredited environmental or food safety laboratories, IQ/OQ/PQ qualification is effectively mandatory. It provides the documented evidence that regulators and accreditation bodies require to confirm that the equipment contributes to reliable, reproducible results. Laboratories should request IQ/OQ/PQ documentation support from equipment suppliers as part of the purchasing process.
How do solvent reduction and green chemistry claims relate to certification?
Solvent reduction and green chemistry claims are performance characteristics, not certifications in the formal sense. A system marketed as using less than 100 mL of organic solvent per sample, or as eliminating the need for dichloromethane, is making a verifiable performance claim, but this is distinct from holding a specific environmental certification. That said, these claims do intersect with regulatory and institutional requirements in meaningful ways.
Many European laboratories are subject to occupational health and safety regulations that restrict or require documentation of exposure to hazardous solvents, including dichloromethane, which is classified as a substance of very high concern under REACH. A system that demonstrably eliminates dichloromethane use can directly support a laboratory’s compliance with these regulations and its obligations under REACH and related EU chemical safety legislation.
Green chemistry performance also relates to ISO 14001, the environmental management standard. Laboratories holding or pursuing ISO 14001 certification may be required to demonstrate continuous improvement in solvent waste reduction and chemical exposure. Documented solvent consumption data from an automated system supports this evidence base. When evaluating supplier claims, laboratories should ask for validation data, not just marketing statements, that quantifies solvent consumption per sample type and confirms the absence of cross-contamination under real operating conditions.
What certifications should a lab verify before purchasing automated sample prep equipment?
Before purchasing an automated sample preparation system, laboratories should verify a defined set of certifications and qualifications that together confirm the equipment is legally compliant, technically validated, and compatible with their accreditation requirements. No single certification covers everything, a thorough evaluation spans the manufacturer, the equipment, and the supplier.
- CE marking: Confirm the system carries CE marking and that the manufacturer can provide the Declaration of Conformity. This is a non-negotiable baseline for equipment used in Europe.
- Manufacturer ISO 9001 certification: Confirms the manufacturer operates under a documented quality management system, which supports traceability and consistency in production.
- IQ/OQ/PQ documentation support: Ask whether the supplier provides qualification protocols and whether on-site support for IQ/OQ/PQ execution is available. For ISO 17025 labs, this is essential.
- Method validation data: Request published or documented validation data demonstrating that the system performs within the acceptance criteria of the regulatory methods you use, whether EPA, CEN, or EU regulation-based.
- Material compatibility documentation: For PFAS analysis, verify that the system’s flow path is fully inert and Teflon-free. For dioxin and PCB work, confirm that cross-contamination is structurally eliminated by design.
- Analytical standards traceability: If the supplier also provides reference materials or standards, confirm these are produced by manufacturers holding ISO 9001, ISO/IEC 17025, and ISO 17034 accreditation.
- Regulatory method compatibility: Confirm explicitly whether the system has been configured or validated for the EPA or CEN methods relevant to your work, and whether the supplier offers pre-installation programming and application testing.
Purchasing decisions based solely on price or throughput claims, without verifying this certification and validation foundation, expose laboratories to significant risk, including failed accreditation audits, invalid data, and regulatory non-compliance.
How DSP-Systems supports laboratory certification requirements
DSP-Systems supplies and configures automated sample preparation systems that are specifically designed to meet the certification and compliance demands described throughout this article. Their offering addresses each of the key verification points a laboratory should check before purchasing:
- All systems supplied carry CE marking and are sourced from manufacturers operating under ISO 9001-certified quality management systems.
- IQ/OQ/PQ qualification support is available, with pre-installation programming and application testing included as part of the delivery process.
- Systems such as the GO-EHT platform are backed by peer-reviewed validation data published against EPA 1613B, EPA 1668A, and EU regulatory frameworks for dioxins and PCBs.
- The LabTech SPE systems feature fully inert, Teflon-free flow paths, purpose-built for PFAS and POP analysis where material compatibility is critical.
- Solvent consumption is documented at less than 100 mL per sample without dichloromethane, supporting REACH compliance and ISO 14001 environmental management objectives.
- Analytical standards supplied by DSP-Systems are produced by manufacturers holding ISO 9001, ISO/IEC 17025, and ISO Guide 34 accreditation.
Laboratories evaluating automated sample prep equipment for regulated contaminant analysis are welcome to contact DSP-Systems directly to discuss certification documentation, method compatibility, and qualification support for their specific workflows.
Veelgestelde vragen
Can an automated sample preparation system be used across multiple regulatory frameworks (e.g., both EPA and EU methods) without separate validation for each?
Yes, but each regulatory framework will require its own documented validation, even if the same physical system is used. A system validated against EPA 1613B for dioxin analysis, for example, cannot automatically be considered validated for EU Regulation 2019/1793 compliance without additional method-specific performance data. Laboratories working across multiple frameworks should ask suppliers whether cross-method validation data is available and whether the system’s configuration can be adjusted or pre-programmed for each method without compromising the other validations.
What happens if our lab's accreditation audit finds that our automated sample prep system lacks proper qualification documentation?
An accreditation body such as those operating under ISO/IEC 17025 can flag missing IQ/OQ/PQ documentation as a major non-conformity, which may result in suspension of accreditation for the affected methods or a requirement to requalify the equipment before results can be reported. In the worst case, data generated without proper qualification documentation may be deemed invalid, potentially triggering costly re-analysis or regulatory consequences. To avoid this, laboratories should treat IQ/OQ/PQ documentation as a pre-requisite rather than a post-installation task, and confirm that supplier support for qualification is included in the purchasing agreement.
How often should automated sample preparation systems be requalified after initial IQ/OQ/PQ?
Requalification intervals depend on the laboratory’s quality framework, the frequency of use, and any changes to the system, such as software updates, hardware repairs, or relocation. Under ISO/IEC 17025 and GMP environments, periodic performance qualification (PQ) is typically required at least annually, and requalification is mandatory after any significant change that could affect system performance. Laboratories should establish a documented requalification schedule as part of their equipment management procedures and confirm with their supplier whether updated OQ/PQ protocols are provided following firmware or software changes.
Is it possible to validate an automated SPE system in-house, or does validation always require support from the equipment supplier?
In-house validation is technically possible if the laboratory has the expertise, reference materials, and documented protocols to execute it, and many ISO/IEC 17025-accredited labs do perform internal method validation as a matter of routine. However, for complex automated systems, supplier-supported qualification significantly reduces the risk of gaps in the technical documentation that accreditation bodies may scrutinize. A practical approach is to use the supplier’s IQ/OQ protocols as the foundation and supplement them with in-house PQ runs using your own matrices and target compounds, ensuring the qualification evidence is both technically complete and specific to your actual working conditions.
What are the most common mistakes laboratories make when evaluating automated sample prep systems for compliance purposes?
The most common mistake is prioritizing throughput or price over the availability of method-specific validation data and qualification support, which can result in purchasing a system that cannot be formally qualified for use in a regulated environment. Another frequent error is assuming that CE marking or ISO 9001 manufacturer certification is sufficient evidence of analytical performance, when these only confirm legal market compliance and quality system management respectively. Laboratories should also avoid overlooking material compatibility, particularly for PFAS analysis, where an otherwise well-certified system with incompatible wetted surfaces can produce systematically biased results that undermine the entire analytical workflow.
How should a laboratory document solvent reduction claims from an automated system to satisfy an ISO 14001 audit?
ISO 14001 auditors typically look for objective evidence of environmental performance improvement, so solvent consumption should be recorded at the batch or sample level using the system’s run logs or a dedicated solvent tracking register. Laboratories should document baseline solvent usage from previous manual or semi-automated workflows and compare it against measured consumption from the automated system, expressed per sample or per analytical batch. Supplier-provided validation reports that quantify solvent consumption under defined operating conditions can serve as supporting evidence, but the laboratory’s own operational records are what auditors will primarily examine to confirm that improvements are real, sustained, and measurable.
If we switch from one automated sample prep platform to another, do we need to fully revalidate our analytical methods?
A change in sample preparation platform is considered a significant method change under most quality frameworks, including ISO/IEC 17025 and GLP, and will typically require at minimum a method verification exercise to confirm that the new system produces results equivalent to those from the previous platform. Whether a full revalidation or a bridging study is required depends on how different the new system’s operating principles, materials, and performance characteristics are from the original. Laboratories should document the change through their change control procedure, define acceptance criteria for the equivalence comparison in advance, and retain all comparative data as part of the method’s validation history.
Gerelateerde artikelen
- How does automated sample preparation support green chemistry initiatives?
- What is the difference between modular and monolithic lab automation systems?
- What is the role of software in controlling automated lab workflows?
- How does automation help labs comply with occupational health regulations?
- What types of samples can be processed with automation?
Deze inhoud is gegenereerd met behulp van AI en kan fouten bevatten.