What is the difference between open and closed automation platforms?

What is the difference between open and closed automation platforms?

An open automation platform allows laboratories to integrate instruments and software from multiple vendors, while a closed automation platform is a self-contained system where hardware, software, and consumables come from a single manufacturer and are designed to work exclusively together. The right choice depends on your laboratory’s analytical scope, existing infrastructure, and long-term flexibility needs. The questions below unpack each dimension of this decision in detail.

What makes a laboratory automation platform ‘open’ or ‘closed’?

A laboratory automation platform is considered open when it supports third-party instrument integration, uses standardized communication protocols, and allows the laboratory to build workflows across equipment from different manufacturers. A closed platform is defined by proprietary design: instruments, reagents, software, and consumables are engineered as a unified system that operates only within the manufacturer’s ecosystem.

The distinction goes beyond hardware. Software architecture plays an equally important role. Open platforms typically rely on protocols such as SiLA 2 or OPC UA, which allow devices to communicate regardless of brand. Closed platforms use proprietary control software that locks the user into a defined set of compatible modules. Neither architecture is inherently superior, each reflects a deliberate design philosophy with real consequences for how a lab operates day to day.

In practice, many modern systems sit somewhere between the two extremes. A platform may be open at the instrument level but closed at the data or reagent level. Understanding exactly where the openness begins and ends is essential before making a purchasing decision.

How does an open platform handle instrument integration?

An open automation platform handles instrument integration through standardized communication interfaces that allow devices from different manufacturers to exchange data and receive commands within a shared workflow. Rather than requiring proprietary connectors or software licenses, open platforms use published protocols that instrument vendors can build against independently.

In practical terms, this means a laboratory can connect a liquid handler from one supplier, a centrifuge from another, and a detection instrument from a third, all coordinated through a central scheduling layer. The scheduling software tracks sample status, manages timing, and routes samples between stations without requiring manual handoffs.

The degree of integration achievable depends on how well each instrument’s driver or API has been implemented. Some instruments offer full bidirectional communication, meaning the platform can both send commands and receive status updates in real time. Others only support one-way triggering, which limits how tightly they can be incorporated into an automated sequence. Laboratories evaluating an open platform should verify the integration depth available for each specific instrument they plan to include, not just whether the instrument is listed as compatible.

What are the advantages of a closed automation platform?

The primary advantage of a closed automation platform is reliability through design coherence. Because every component is engineered and validated together by a single manufacturer, closed systems deliver predictable, reproducible performance without the compatibility uncertainties that can arise when integrating third-party instruments. Setup is typically faster, and the vendor provides unified technical support across the entire system.

For laboratories running high-throughput, routine analyses on well-defined sample types, a closed platform removes significant complexity. Method parameters are pre-optimized, validation data is often available directly from the manufacturer, and software updates are managed centrally. This reduces the internal expertise required to maintain the system and shortens the time from installation to productive operation.

Closed platforms also tend to perform better in regulated environments where method traceability and audit trails are mandatory. When a single vendor controls the entire analytical chain, generating the documentation required for regulatory submissions or accreditation audits is more straightforward. The trade-off is reduced flexibility, but for laboratories with a stable and well-defined analytical menu, that trade-off is often worthwhile.

When should a laboratory choose an open platform over a closed one?

A laboratory should choose an open automation platform when its analytical workload spans multiple contaminant classes, sample matrices, or detection technologies that no single manufacturer’s closed system can adequately cover. Open platforms are also the better choice when a laboratory already owns validated instruments it needs to retain, or when future analytical scope is expected to expand in directions that are not yet defined.

Contract testing laboratories and research-oriented facilities are the most natural fit for open platforms. These organizations frequently need to adapt workflows to new regulatory requirements, add emerging contaminant targets, or serve clients with diverse analytical needs. Locking into a closed ecosystem in these settings can create bottlenecks when the next analytical challenge does not align with the incumbent vendor’s product roadmap.

Open platforms also make sense when a laboratory operates across multiple sites and needs a common software layer to coordinate instruments that may differ by location. Standardizing on an open scheduling and data management system allows each site to use locally available instruments while still sharing methods, results, and quality control data across the organization.

How do open and closed platforms compare on cost and maintenance?

Closed platforms generally carry lower upfront integration costs because the system arrives pre-configured and validated. Open platforms typically require a larger initial investment in integration engineering, software licensing, and validation work, but they offer greater long-term flexibility to add instruments or modify workflows without being tied to a single vendor’s pricing.

Upfront and integration costs

With a closed system, the purchase price covers a complete, tested solution. The manufacturer handles compatibility, and the laboratory’s internal effort is focused on installation and operator training rather than systems integration. Open platforms require the laboratory or a systems integrator to define and build the workflow, connect each instrument’s driver, and validate the assembled system as a whole. This work takes time and requires technical expertise that not every laboratory has in-house.

Long-term maintenance and vendor dependency

Maintenance costs for closed systems are predictable but can be high, particularly for consumables and service contracts where the vendor holds a monopoly. If the manufacturer discontinues a component or exits the market, the laboratory may face significant disruption. Open platforms distribute risk across multiple vendors, if one supplier’s pricing becomes unfavorable or their product is discontinued, individual components can be replaced without rebuilding the entire workflow. However, maintaining compatibility as individual instruments are upgraded or replaced requires ongoing technical attention that closed systems do not demand.

Which platform type is better for PFAS and persistent organic pollutant analysis?

For PFAS and persistent organic pollutant (POP) analysis, closed or purpose-built automated platforms are generally the stronger choice. These contaminant classes impose strict requirements around solvent compatibility, cross-contamination prevention, and method reproducibility that are most reliably met by systems designed specifically for the task rather than assembled from general-purpose components.

PFAS analysis presents a particular challenge: even trace amounts of fluoropolymer materials in flow paths can introduce background contamination that invalidates results. Systems purpose-built for PFAS work use fully inert flow paths free of Teflon and other fluoropolymers, a design requirement that is difficult to guarantee when assembling an open platform from components not originally specified for PFAS work.

For dioxins, PCBs, and PBDEs, the critical requirements are thorough lipid removal, precise column sequencing, and minimal solvent consumption. Fully automated closed systems designed for persistent organic pollutant cleanup can reduce solvent use to below 100 mL per sample without dichloromethane, and because samples never come into direct contact with the instrument hardware, cross-contamination between samples is eliminated. Achieving the same level of performance through an open platform is possible but requires careful selection and validation of every component in the extraction and purification chain.

Open platforms remain relevant for laboratories analyzing a broad mix of contaminants where no single closed system covers the full analytical scope. In those cases, a modular approach using purpose-built extraction and cleanup modules connected through an open scheduling layer can combine the reliability of specialized hardware with the flexibility of open architecture.

How DSP-Systems supports your choice of automation platform

DSP-Systems specializes in automated sample preparation solutions designed specifically for the analysis of persistent organic pollutants, PFAS, and related environmental contaminants. Whether your laboratory is evaluating a purpose-built closed system or looking to integrate specialized modules into a broader workflow, DSP-Systems provides the expertise and product portfolio to match your analytical needs.

  • The GO-EHT purification platform delivers fully automated sample cleanup for dioxins, PCBs, PBDEs, and PCNs across food, feed, soil, water, and air matrices, with solvent consumption below 100 mL per sample and zero cross-contamination risk
  • The AutoEmpore provides high-throughput large-volume water extraction for PFAS, pesticides, hormones, and SVOCs in flexible multi-channel configurations
  • The SPE2000 offers advanced automated solid-phase extraction with fully inert, Teflon-free flow paths suited to PFAS and endocrine disruptor applications
  • Pre-installation programming, method development support, and configuration aligned with EPA and CEN standards are included as part of the service
  • Training, turn-key lab setups, and long-term technical support ensure your team gets maximum value from the chosen platform

If you are comparing automation platforms for contaminant analysis and want guidance tailored to your specific matrix types and regulatory requirements, contact DSP-Systems directly to discuss which solution fits your laboratory’s workflow.

Veelgestelde vragen

Can we start with a closed platform and migrate to an open one later if our analytical needs expand?

Migration is possible but rarely straightforward. Closed platforms are designed around proprietary workflows, so transitioning to an open architecture typically means re-validating methods, retraining staff, and investing in new integration work rather than simply adding instruments. A more practical approach is to evaluate your five-year analytical roadmap before committing: if significant scope expansion is likely, starting with an open or modular platform from the outset is almost always more cost-effective than retrofitting later.

How do we validate an open automation platform for regulatory submissions or accreditation purposes?

Validating an open platform requires treating the assembled system as a whole rather than validating each instrument in isolation. You will need to demonstrate that the integrated workflow produces results equivalent to your reference methods, with documented evidence covering instrument qualification (IQ/OQ/PQ), software validation, and end-to-end method performance. Working with a systems integrator experienced in your regulatory framework (EPA, ISO 17025, EU environmental directives) can significantly reduce the time and internal effort required to build the necessary documentation package.

What questions should we ask a vendor to determine how 'open' their platform truly is?

Ask specifically whether the platform supports SiLA 2 or OPC UA, whether third-party instrument drivers can be added without vendor approval, and whether data can be exported in open formats without proprietary middleware. Also ask whether the software licensing model restricts which instruments or modules you can connect, and request a list of instruments that have been independently integrated by other customers rather than just a theoretical compatibility list. The gap between marketed openness and practical openness often becomes clear in the answers to these specific questions.

How do we assess whether an automated sample preparation system is truly free of PFAS contamination risks?

Request a full bill of materials for all wetted components, including tubing, fittings, valves, and sample vessels, and verify that none contain PTFE, FEP, PVDF, or other fluoropolymers. Ask the vendor for background contamination data generated under realistic sample conditions, not just blank solvent runs. Purpose-built PFAS systems should be able to provide method detection limit data demonstrating that instrument background does not contribute meaningfully to reported results at the concentrations relevant to your regulatory thresholds.

What internal expertise does a laboratory need to successfully operate and maintain an open automation platform?

At minimum, an open platform requires at least one staff member with a working understanding of software integration, instrument communication protocols, and workflow scheduling logic. For larger or more complex systems, a dedicated automation specialist or a retained relationship with a systems integrator is strongly advisable. Closed platforms have a lower internal expertise threshold, which is a genuine advantage for smaller laboratories or those without a dedicated instrumentation team. Honestly assessing your team’s current capabilities alongside your analytical requirements is an important part of the platform selection process.

Can specialized closed-system modules like automated SPE or purification systems be incorporated into a broader open platform workflow?

Yes, and this hybrid approach is increasingly common in laboratories with diverse analytical menus. Purpose-built extraction or cleanup modules can often be integrated into an open scheduling layer as discrete, self-contained stations, with the open platform managing sample handoff, sequencing, and data routing around them. The key is confirming that the module exposes a compatible API or communication interface and that the integration has been validated for your specific workflow. DSP-Systems’ instruments, for example, are designed to support both standalone closed-system operation and integration into broader automated environments.

How should a multi-site laboratory standardize automation across locations that use different instruments?

The most effective strategy is to standardize at the software and data layer rather than trying to enforce identical hardware across all sites. An open scheduling and laboratory informatics platform allows each site to use locally available or regionally supported instruments while sharing a common method library, quality control framework, and data reporting structure. Where specific analytical performance is non-negotiable, such as for PFAS or POPs cleanup, deploying the same purpose-built module at each site ensures method equivalency even if the surrounding instrument landscape differs.