Column sets

Column sets and commitment to excellence

The GO-EHT sample preparation systems utilize a certified set of four high-performance chromatography columns for each sample. These clean-up columns are vacuum-sealed and designed for ease of use.

During the purification process, the columns are heated, significantly enhancing chromatography efficiency while requiring only a minimal volume of organic solvent. This process also reduces exposure for both the operator and the environment.

GO-EHT column sets are suitable for analyzing food, feed, and environmental matrices. Each complete set includes four distinct columns along with the necessary tubing:

  • Silver nitrate impregnated silica column
  • Sulphuric acid impregnated silica column
  • Aluminum/Zr oxide concentration column
  • Carbon/florisil concentration column
  • Tubing set
Column set 18mm

Depending on the nature of samples and desired column set capacity we provide the following types of column sets

Cat. NumberProduct descriptionCapacityApplicationDelivery time
X300-002-2420-720φ Column set (DXN/PCB)< 5g fatDioxins, PCB, PBDE, PCN1 week
P10000270467-0018φ GO209 Column set (DXN/PCB)< 2g fatDioxins, all 209 PCB (EPA), PBDE, PCN1 week
X300-002-1320-718φ Column set (DXN/PCB)<1g fat *Dioxins, PCB, PBDE, PCN4-6 weeks
X300-002-1330-718φ Column set (DXN) <1g fat **Dioxins only4-6 weeks

* For analysis of Dioxin and PCBs in environmental samples and/or samples with low fat content (<1g)
** For analysis of Dioxins only in environmental samples in and/or samples with low fat content (<1g)

Quality Control

Miura Co. Ltd. in Japan is an ISO 17025 accredited organization having a comprehensive quality system in place assuring constant commitment to excellence. After production of new column set batches, they are tested in accordance with strict internal quality control protocol:

  • Out of every 150 newly produced columns one set is examined by QC-dept.
  • The recovery rates of all PCDD/Fs and PCBs must be> 70%
  • The blank values PCDD / Fs must be <0.5 pg TEQ / column set
  • The blank DL-PCBs must be <0.05 pg TEQ / column set

Only if the above requirements are met, a batch passes Miura quality control with a column set certificate of quality.
These certificates contain a report of blank and recovery tests performed and provides corresponding chromatograms.
Column set certificates of quality are provided with every delivery of column sets and can be viewed and downloaded in the download section